首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于可调谐激光吸收光谱技术的二硫化碳中红外光谱参数测量
引用本文:管林强,邓昊,姚路,聂伟,许振宇,李想,臧益鹏,胡迈,范雪丽,杨晨光,阚瑞峰.基于可调谐激光吸收光谱技术的二硫化碳中红外光谱参数测量[J].物理学报,2019,68(8):84204-084204.
作者姓名:管林强  邓昊  姚路  聂伟  许振宇  李想  臧益鹏  胡迈  范雪丽  杨晨光  阚瑞峰
作者单位:1. 中国科学院合肥物质科学研究院, 安徽光学精密机械研究所, 环境光学与技术重点实验室, 合肥 230031; 2. 中国科学技术大学, 合肥 230026; 3. 中国科学院长春光学精密机械与物理研究所, 长春 130000
基金项目:国家重点研发计划(批准号:2016YFC201100)资助的课题.
摘    要:采用4.6μm附近的量子级联激光器作为光源,搭建了一套二硫化碳(CS2)吸收光谱测量系统,结合可调谐二极管激光吸收光谱技术,对光谱范围为2178.99—2180.79 cm-1的CS2吸收光谱展开了深入研究,重点测量了2180.5—2180.74 cm~(-1)的四条吸收谱线,利用基于非线性最小二乘的多元线性回归算法对CS2吸收光谱进行拟合,精确得到了该范围内谱线的中心波长、线强以及空气展宽系数等光谱参数.经计算,对应谱线线强不确定度小于5%,空气展宽系数不确定度小于15%,这个结果可作为免标定CS2红外光谱探测的基础光谱参数,对痕量CS2气体传感具有重要意义.未来我们将进一步开展2170—2200 cm-1整个谱段的CS2谱线参数的测量,以期填补其在HITRAN和GEISA数据库光谱参数的空白.

关 键 词:二硫化碳(CS2)  量子级联激光器  可调谐二极管激光吸收光谱  光谱参数
收稿时间:2018-12-05

Measurement of middle infrared spectroscopic parameters of carbon disulfide based on tunable diode laser absorption spectroscopy
Guan Lin-Qiang,Deng Hao,Yao Lu,Nie Wei,Xu Zhen-Yu,Li Xiang,Zang Yi-Peng,Hu Mai,Fan Xue-Li,Yang Chen-Guang,Kan Rui-Feng.Measurement of middle infrared spectroscopic parameters of carbon disulfide based on tunable diode laser absorption spectroscopy[J].Acta Physica Sinica,2019,68(8):84204-084204.
Authors:Guan Lin-Qiang  Deng Hao  Yao Lu  Nie Wei  Xu Zhen-Yu  Li Xiang  Zang Yi-Peng  Hu Mai  Fan Xue-Li  Yang Chen-Guang  Kan Rui-Feng
Institution:1. Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, China Academy of Sciences, Hefei 230031, China; 2. University of Science and Technology of China, Hefei 230026, China; 3. Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130000, China
Abstract:Carbon disulfide (CS2) is a toxic volatile sulfur compound with flammability and harmfulness, which can seriously harm the human health and threaten the industrial production safety. Therefore, it is of high importance for monitoring CS2 concentration in the air. Tunable diode laser absorption spectroscopy is very suitable for the detection of trace gas for it possesses high sensitivity and fast response. And the precise knowledge of spectroscopic parameters is essential for deducing the CS2 concentration. However, primary database including HITRAN and GEISA lacks spectroscopic parameters of CS2. Thus, to address this issue, a measurement system of absorption spectrum is built for determining spectroscopic parameters by using a quantum cascade laser with narrow linewidth and high output power operating near 4.6 um as a light source. In this paper, direct absorption spectroscopy is used to measure the CS2 absorption spectra under different sample pressures and the environment temperature is controlled at 296 K, which is adjusted by an air conditioner. We intensively study the absorption spectra of CS2 in a range between 2178.99 and 2180.79 cm–1.According to the relevant reports and the need of actual measurement, four absorption lines are mainly measured in a range of 2180.5?2180.74 cm–1. Combining with the multiple linear regression algorithm based on the nonlinear least-square method and Beer-Lambert law, the integrated area and Lorentz line width of measured CS2 absorption spectrum can be determined. Then the spectroscopic parameters including absorption line intensity and air broadening coefficient are precisely obtained by linearly fitting the integrated areas and Lorentz line widths of CS2 absorption spectra at different pressures. Moreover, nitrous oxide (N2O) absorption spectrum with high spectral resolution is measured to calibrate the central position of carbon disulfide absorption line according to its known line position extracted from HITRAN database and the results obtained by etalon. The calculated results show that the uncertainty of line intensity and air broadening coefficient are less than 5% and 15%, respectively. It demonstrates that the measured spectroscopic parameters of four absorption lines for this study can be recorded in the database of HITRAN, which is very important for trace gas sensing of CS2. In the future, we will further improve the system for measuring CS2 absorption line parameters to fill in the gaps in their spectral parameters in HITRAN and GEISA databases.
Keywords:carbon disulfide (CS2)  quantum cascade laser  tunable diode laser absorption spectroscopy  spectroscopic parameters
本文献已被 CNKI 等数据库收录!
点击此处可从《物理学报》浏览原始摘要信息
点击此处可从《物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号