首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement of k 0 and Q 0 values for iridium isotopes
Authors:C. Chilian  L. Sneyers  P. Vermaercke  G. Kennedy
Affiliation:1. Ecole Polytechnique, P.O.Box 6079, Downtown, Montreal, QC, H3C 3A7, Canada
2. SCK?CEN, Belgian Nuclear Research Centre, Boeretang 200, 2400, Mol, Belgium
Abstract:
There is an increasing demand for the chemical analysis of new materials containing iridium. The k 0-method is an excellent method for the analysis of new materials but measured k 0-values and Q 0-values have been lacking for 191Ir(n,γ)192Ir, which offers greater sensitivity than 193Ir(n,γ)194Ir. In this work, the Q 0-values were determined for the two reactions by the two-channel method, using five irradiation channels in two research reactors in Belgium and Canada. These measured Q 0-values enabled the first determination of the resonance neutron Cd transmission factors for these two capture reactions, confirming suspicions that they are much less than unity. At the two laboratories, k 0-values were measured for 192Ir and 194Ir and there was good agreement between the two laboratories. The k 0-values for 192Ir are original measurements, while those for 194Ir are in good agreement with previously published values.
Keywords:
本文献已被 SpringerLink 等数据库收录!