Detection of VX contamination in soil through solid-phase microextraction sampling and gas chromatography/mass spectrometry of the VX degradation product bis(diisopropylaminoethyl)disulfide
Authors:Hook Gary L  Kimm Gregory  Koch David  Savage Paul B  Ding Bangwei  Smith Philip A
Institution:Uniformed Services University of the Health Sciences, Department of Preventive Medicine and Biometrics, Bethesda, MD 20814-4799, USA.
Abstract:A solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) sampling and analysis method was developed for bis(diisopropylaminoethyl)disulfide (a degradation product of the nerve agent VX) in soil. A 30-min sampling time with a polydimethylsiloxane-coated fiber and high temperature alkaline hydrolysis allowed detection with 1.0 microg of VX spiked per g of agricultural soil. The method was successfully used in the field with portable GC-MS instrumentation. This method is relatively rapid (less than 1 h), avoids the use of complex preparation steps, and enhances analyst safety through limited use of solvents and decontamination of the soil before sampling.