首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Detection of the 35S promoter in transgenic maize via various isothermal amplification techniques: a practical approach
Authors:Celine Zahradnik  Claudia Kolm  Roland Martzy  Robert L Mach  Rudolf Krska  Andreas H Farnleitner  Kurt Brunner
Institution:1. Institute of Chemical Engineering, Center for Analytical Chemistry, IFA-Tulln, Vienna University of Technology, Konrad Lorenz Str. 20, 3430, Tulln, Austria
3. Center for Analytical Chemistry, IFA-Tulln, University of Natural Resources and Applied Life Sciences Vienna, Konrad Lorenz Str. 20, 3430, Tulln, Austria
2. Gene Technology Group, Institute of Chemical Engineering, Vienna University of Technology, Gumpendorfer Str. 1a, 1060, Vienna, Austria
Abstract:In 2003 the European Commission introduced a 0.9 % threshold for food and feed products containing genetically modified organism (GMO)-derived components. For commodities containing GMO contents higher than this threshold, labelling is mandatory. To provide a DNA-based rapid and simple detection method suitable for high-throughput screening of GMOs, several isothermal amplification approaches for the 35S promoter were tested: strand displacement amplification, nicking-enzyme amplification reaction, rolling circle amplification, loop-mediated isothermal amplification (LAMP) and helicase-dependent amplification (HDA). The assays developed were tested for specificity in order to distinguish between samples containing genetically modified (GM) maize and non-GM maize. For those assays capable of this discrimination, tests were performed to determine the lower limit of detection. A false-negative rate was determined to rule out whether GMO-positive samples were incorrectly classified as GMO-negative. A robustness test was performed to show reliable detection independent from the instrument used for amplification. The analysis of three GM maize lines showed that only LAMP and HDA were able to differentiate between the GMOs MON810, NK603, and Bt11 and non-GM maize. Furthermore, with the HDA assay it was possible to realize a detection limit as low as 0.5 %. A false-negative rate of only 5 % for 1 % GM maize for all three maize lines shows that HDA has the potential to be used as an alternative strategy for the detection of transgenic maize. All results obtained with the LAMP and HDA assays were compared with the results obtained with a previously reported real-time PCR assay for the 35S promoter in transgenic maize. This study presents two new screening assays for detection of the 35S promoter in transgenic maize by applying the isothermal amplification approaches HDA and LAMP.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号