首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Collection method for chemical particulates on surfaces with detection using thermal desorption-ion trap mass spectrometry
Authors:KJ Ewing  D Gibson  J Sanghera  F Miklos
Institution:1. Naval Research Laboratory, Code 5620, Washington, DC, United States;2. Sotera Defense Solutions, 2121 Cooperative Way, Herndon, VA, United States
Abstract:Successful analysis of particulate/low vapor pressure analytes such as explosives and toxic chemicals, and commercial pesticides require new sampling tools that enable detection of these analytes using current vapor phase detection instruments. We describe a sampling approach that uses stainless steel screens coated with a sticky polydimethyl siloxane (PDMS) coating to capture particulates from surfaces. Preliminary results for the collection of dimethyl methylphosphonate (DMMP) sorbed onto silica gel (SG) particulates (DMMP/SG) from a surface with subsequent analysis by thermal desorption-cylindrical ion trap mass spectrometry (TD-CITMS) are reported.
Keywords:Chemical particulates  Collection  Surfaces  Screens
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏