首页 | 本学科首页   官方微博 | 高级检索  
     

高效液相色谱/挥发激光散射检测器测定奶粉和鸟粪中的甾体化合物
引用本文:冯埃生,邹汉法,张冰,汪海林,张玉奎. 高效液相色谱/挥发激光散射检测器测定奶粉和鸟粪中的甾体化合物[J]. 色谱, 1997, 15(2): 102-105
作者姓名:冯埃生  邹汉法  张冰  汪海林  张玉奎
作者单位:中国科学院大连化学物理研究所
摘    要:
利用反相高效液相色谱/挥发激光散射检测器发展了分析甾体化合物的新方法,采用甲醇和水溶液为冲洗体系,梯度淋洗,12种甾体类化合物在35min内得到很好的分离。方法简单快速,不需衍生,样品经固相萃取预处理,回收率介于84.0%~102.8%之间,响应值和浓度不呈简单的线性关系,在5~50mg/L浓度范围内对峰面积与浓度进行对数线性回归分析,得回归系数大于0.99。

关 键 词:反相高效液相色谱法  挥发激光散射检测器  奶粉  鸟粪  甾体化合物  

Determination of Steroids in Milk Powder and Birds' Feces by High Performance Liquid Chromatography Coupled with Evaporative Light Scattering Detector
Feng Aisheng, Zou Hanfa, Zhang Bing, Wang Hailin and Zhang Yukui. Determination of Steroids in Milk Powder and Birds' Feces by High Performance Liquid Chromatography Coupled with Evaporative Light Scattering Detector[J]. Chinese journal of chromatography, 1997, 15(2): 102-105
Authors:Feng Aisheng   Zou Hanfa   Zhang Bing   Wang Hailin  Zhang Yukui
Affiliation:National Chromatographic R. & A. Center, Dalian Institute of Chemical Physics, the Chinese Academy of Sciences, Dalian, 116011.
Abstract:
In this paper, a new, simple and rapid method for the analysis of steroids by reversed-phase high performance liquid chromatography (HPLC) coupled with evaporative light scattering detector (ELSD) is presented. A good resolution of the 12 steroids is obtained within 35 min with a gradient elution using a binary mobile phase composed of methanol and water. The analytical column used was 2.0mm x 150mm, packed with BDS (particle size 5microm) and the mobile phase flow rate was 0.2mL/min. Nebulizer gas flow rate and drift tube temperature, the two critical parameters for determining the reproducibility and signal-to-noise ratio of ELSD were 2.00mL/min and 95 degrees C, respectively. The response of the ELSD was non-linear as a result of basic light-scattering principles, the calibration curve by plotting lnY vs lnX (Y, X stand for peak area and concentration, respectively) shows a good linearity in the range of 5-50mg/L with a correlation coefficient higher than 0.99 for individual steroid and with relative standard deviation less than 6.92%. This method has been applied to the determination of steroids in milk powder and birds' feces, solid phase extraction on reverse phase bonded C18 (5mL/500mg) was used to treat the samples efficiently. The recoveries of the steroids were between 84.0%-102.8%.
Keywords:reversed phase high performance liquid chromatography   evaporative light scattering detector   milk   feces   steroids