Abstract: | The temperature regime of a filtering unit being cooled after an accident at a nuclear power plant is considered. A mathematical
model is developed; the model is based on three-dimensional equations of thermohydrodynamics and takes into account heat-transfer
mechanisms (convection, heat conduction, and radiation). For the unit variants considered, the maximum value of temperature
in the sorbing module is less than 300°C, and the temperature reserve is 20–50°C.
__________
Translated from Prikladnaya Mekhanika i Tekhnicheskaya Fizika, Vol. 48, No. 6, pp. 92–102, November–December, 2007. |