首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Analysis of the temperature regime of operation of a filtering unit
Authors:V I Melikhov  O I Melikhov  Yu V Parfenov  S E Yakush
Institution:(1) Elektrogorsk Research and Engineering Center on NPP Safety, Elektrogorsk 142530, Moscow Region
Abstract:The temperature regime of a filtering unit being cooled after an accident at a nuclear power plant is considered. A mathematical model is developed; the model is based on three-dimensional equations of thermohydrodynamics and takes into account heat-transfer mechanisms (convection, heat conduction, and radiation). For the unit variants considered, the maximum value of temperature in the sorbing module is less than 300°C, and the temperature reserve is 20–50°C. __________ Translated from Prikladnaya Mekhanika i Tekhnicheskaya Fizika, Vol. 48, No. 6, pp. 92–102, November–December, 2007.
Keywords:filtering unit  NPP safety  natural heat convection  thermal conductivity  heat transfer
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏