首页 | 本学科首页   官方微博 | 高级检索  
     


Magnetic ionic liquids as non-conventional extraction solvents for the determination of polycyclic aromatic hydrocarbons
Authors:Marí  a J. Trujillo-Rodrí  guez,Omprakash Nacham,Kevin D. Clark,Veró  nica Pino,Jared L. Anderson,Juan H. Ayala,Ana M. Afonso
Affiliation:1. Departamento de Química (Área de Química Analítica), Universidad de La Laguna (ULL), La Laguna, Tenerife, 38206, Spain;2. Department of Chemistry, Iowa State University, Ames, IA, 50011, USA
Abstract:This work describes the applicability of magnetic ionic liquids (MILs) in the analytical determination of a group of heavy polycyclic aromatic hydrocarbons. Three different MILs, namely, benzyltrioctylammonium bromotrichloroferrate (III) (MIL A), methoxybenzyltrioctylammonium bromotrichloroferrate (III) (MIL B), and 1,12-di(3-benzylbenzimidazolium) dodecane bis[(trifluoromethyl)sulfonyl)]imide bromotrichloroferrate (III) (MIL C), were designed to exhibit hydrophobic properties, and their performance examined in a microextraction method for hydrophobic analytes. The magnet-assisted approach with these MILs was performed in combination with high performance liquid chromatography and fluorescence detection. The study of the extraction performance showed that MIL A was the most suitable solvent for the extraction of polycyclic aromatic hydrocarbons and under optimum conditions the fast extraction step required ∼20 μL of MIL A for 10 mL of aqueous sample, 24 mmol L−1 NaOH, high ionic strength content of NaCl (25% (w/v)), 500 μL of acetone as dispersive solvent, and 5 min of vortex. The desorption step required the aid of an external magnetic field with a strong NdFeB magnet (the separation requires few seconds), two back-extraction steps for polycyclic aromatic hydrocarbons retained in the MIL droplet with n-hexane, evaporation and reconstitution with acetonitrile. The overall method presented limits of detection down to 5 ng L−1, relative recoveries ranging from 91.5 to 119%, and inter-day reproducibility values (expressed as relative standard derivation) lower than 16.4% for a spiked level of 0.4 μg L−1 (n = 9). The method was also applied for the analysis of real samples, including tap water, wastewater, and tea infusion.
Keywords:Ionic liquids   Magnetic ionic liquids   Magnetic-assisted microextraction   Polycyclic aromatic hydrocarbons   High-performance liquid chromatography
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号