首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effective extraction of triazines from environmental water samples using magnetism-enhanced monolith-based in-tube solid phase microextraction
Authors:Meng Mei  Xiaojia Huang  Xiaodong Yang  Qing Luo
Institution:1. State Key Laboratory of Marine Environmental Science, Key Laboratory of the Ministry of Education for Coastal and Wetland Ecosystem, College of the Environment and Ecology, Xiamen University, Xiamen 361005, China;2. College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China;3. Department of Materials Science and Engineering, College of Materials, Xiamen University, Xiamen 361005, China
Abstract:This article reports on the effective extraction of triazines from environmental water samples using magnetism-enhanced monolith-based in-tube solid phase microextraction (ME-MB/IT-SPME). Firstly, monolithic poly (octyl methacrylate-co-ethyleneglycol dimethacrylate) capillary column doped with magnetic nanoparticles was synthesized inside a fused silica. After that, the monolithic capillary column was placed inside a magnetic coil that allowed the exertion of a variable magnetic field during adsorption and desorption steps. The effects of intensity of magnetic field, adsorption and desorption flow rate, volume of sample and desorption solvent, pH value and ionic strength in sample matrix on the performance of ME-MB/IT-SPME for triazines were investigated in details. Under the optimized conditions, the developed ME-MB/IT-SPME showed satisfactory quantitative extraction efficiencies of the target analytes between 64.8% and 99.7%. At the same time, the ME-MB/IT-SPME was combined with high-performance liquid chromatography with diode array detection to detect six triazines in water samples. The limits of detection (S/N = 3) and limits of quantification (S/N = 10) were in the ranges of 0.074–0.23 μg/L and 0.24–0.68 μg/L, respectively. The precision of the proposed method was evaluated in terms of intra- and inter-assay variability calculated as relative standard deviation, and it was found that the values were all below 10%. Finally, the developed method was successfully applied for environmental water samples such as farmland, lake and river water with spiked recoveries in the range of 70.7–119%.
Keywords:Magnetism-enhanced in-tube solid phase microextraction  Monolithic capillary column  Triazines  Sample pretreatment  Water
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号