首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Rapid determination of total sulfur in fuels using gas chromatography with atomic emission detection
Authors:Link Dirk D  Baltrus John P  Rothenberger Kurt S  Zandhuis Paul  Minus Donald  Striebich Richard C
Institution:U.S. Department of Energy, National Energy Technology Laboratory, Pittsburgh, PA 15236, USA.
Abstract:The purpose of this study is to determine whether gas chromatography (GC)-atomic emission detection (AED) can be used in a low-resolution mode for rapid, accurate determinations of total sulfur in fuels at trace levels to complement other popular methods of total sulfur analysis. A method for the rapid determination of total sulfur in fuels (called "fast GC-AED") is developed. The method is tested on gasoline, jet fuel, kerosene, and diesel fuel with sulfur concentrations ranging from 125 mg/L down to 2.5 mg/L. Fast GC-AED shows better performance than traditional GC-AED for total sulfur determinations, especially for complex mixtures containing many different sulfur-containing compounds at trace levels. This method also shows that GC-AED can be used for both rapid determinations of total sulfur and traditional determinations of speciated sulfur without requiring equipment changes. Fast GC-AED is competitive with other popular methods for sulfur analysis. The 5-min program that is developed for fast GC-AED is comparable with the time scale of other methods, such as wavelength dispersive X-ray fluorescence and UV-fluorescence (2 to 5 min). Fast GC-AED also compares favorably with UV-fluorescence for trace sulfur determinations, demonstrating accuracy down to 2.5-mg/L sulfur.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏