首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of gamma-hydroxybutyric acid in human urine by capillary electrophoresis with indirect UV detection and confirmation with electrospray ionization ion-trap mass spectrometry
Authors:Baldacci Andrea  Theurillat Regula  Caslavska Jitka  Pardubská Helena  Brenneisen Rudolf  Thormann Wolfgang
Institution:

a Department of Clinical Pharmacology, University of Bern, Murtenstrasse 35, CH-3010, Bern, Switzerland

b Department of Clinical Research, University of Bern, Murtenstrasse 35, CH-3010, Bern, Switzerland

Abstract:γ-Hydroxybutyric acid (GHB), a minor metabolite or precursor of γ-aminobutyric acid (GABA), acts as a neurotransmitter/neuromodulator via binding to GABA receptors and to specific presynaptic GHB receptors. Based upon the stimulatory effects, GHB is widely abused. Thus, there is great interest in monitoring GHB in body fluids and tissues. We have developed an assay for urinary GHB that is based upon liquid–liquid extraction and capillary zone electrophoresis (CZE) with indirect UV absorption detection. The background electrolyte is composed of 4 mM nicotinic acid (compound for indirect detection), 3 mM spermine (reversal of electroosmosis) and histidine (added to reach a pH of 6.2). Having a 50 μm I.D. capillary of 40 cm effective length, 1-octanesulfonic acid as internal standard, solute detection at 214 nm and a diluted urine with a conductivity of 2.4 mS/cm, GHB concentrations ≥2 μg/ml can be detected. Limit of detection (LOD) and limit of quantitation (LOQ) were determined to be dependent on urine concentration and varied between 2–24 and 5–60 μg/ml, respectively. Data obtained suggest that LOD and LOQ (both in μg/ml) can be estimated with the relationships 0.83 κ and 2.1 κ, respectively, where κ is the conductivity of the urine in mS/cm. The assay was successfully applied to urines collected after administration of 25 mg sodium GHB/kg body mass. Negative electrospray ionization ion-trap tandem mass spectrometry was used to confirm the presence of GHB in the urinary extract via selected reaction monitoring of the m/z 103.1→m/z 85.1 precursor–product ion transition. Independent of urine concentration, this approach meets the urinary cut-off level of 10 μg/ml that is required for recognition of the presence of exogenous GHB. Furthermore, data obtained with injection of plain or diluted urine indicate that CZE could be used to rapidly recognize GHB amounts (in μg/ml) that are ≥ 4 κ.
Keywords:Hydroxybutyric acid
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号