Electrocatalytic Application of an Overoxidized Dopamine Film Prepared on a Gold Electrode Surface to Selective Epinephrine Sensing |
| |
Authors: | Teresa Łuczak |
| |
Affiliation: | Faculty of Chemistry, A. Mickiewicz University, Grunwaldzka 6, PL‐60‐780 Poznań, Poland |
| |
Abstract: | A dopamine polymer film was prepared ex situ on a bare gold template from a 10 mM dopamine solution in phosphate buffer, pH 7 followed by an overoxidation in 500 mM NaOH. The modified electrode was used for quantitative determination of epinephrine. A linear relationship between epinephrine concentration and current response was obtained in the range between 2 μM and 800 μM with the detection limit of 0.3 μM. The results have shown that using the overoxidized dopamine film it is possible to perform electrochemical analysis of epinephrine without interference of ascorbic and uric acids. |
| |
Keywords: | Epinephrine Dopamine Gold electrode Modified electrode Electrooxidation |
|
|