首页 | 本学科首页   官方微博 | 高级检索  
     检索      


High power doubly resonant all-intracavity deep blue laser at 447 nm based on sum-frequency-mixing technology
Authors:YongjiYu  Guangyong Jin  Chao Wang  Xinyu Chen  Jiaxi Guo  Yibo Wang
Institution:Institute of Laser Technology,School of Science,Changchun University of Science and Technology,Changchun 130022,China
Abstract:A high power continuous-wave deep blue laser at 447 nm is obtained by using a doubly cavity and a type Π critical phase matching KTP crystal for intracavity sum-frequency-mixing.With the incident pump power of 240 W for the Nd:YAP crystal and 120 W for the other Nd:YAP crystal, the deep blue laser output of 5.7 W at 447 nm with near fundamental mode is obtained, and the beam quality M2 value equals 2.53 in both horizontal and vertical directions at the maximum output power.The power stability is better than 2% at the maximum output power during half an hour.The experimental results show that the intracavity sum-frequency mixing by doubly resonant is an effective method for high power blue laser.
Keywords:
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号