首页 | 本学科首页   官方微博 | 高级检索  
     


Factors that influence the tribo-charging of insulating ducts in suction-type dilute-phase pneumatic transport systems
Authors:Ciprian Dragan  Adrian Samuila  Subhankar Das  Dan Iancu  Mihai Bilici  Lucian Dascalescu
Affiliation:1. University of Poitiers, Poitiers, France;2. Department of Electrical Engineering, Technical University of Cluj-Napoca, Cluj-Napoca, Romania;3. General Electric, Bangalore, India
Abstract:The aim of this study is to refine the understanding of the tribo-electrostatic phenomena that can affect the efficiency of suction-type dilute-phase transport systems. The study was conducted with mm-size ABS-PC particles, a granular material originating from genuine information technology wastes. The tribo-charging process was modelled using the response surface method of experimental design. The controlled variables were the granular material feed rate and the aspirating air speed rate. The monitored variable was the charge imparted to a well-defined section of the duct and which is equal to the charge transferred to the particles passing through that section of the pneumatic transport system. An induction type sensor connected to an electrometer has been employed for the measurements. The data were processed by a virtual instrument developed in LabView. A commercial software package was employed for estimating the effects of the various factors and predicting the optimum operating conditions, which were then confirmed by a final experiment.
Keywords: