首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Sensitive and versatile electrogenerated chemiluminescence biosensing platform for protein kinase based on Ru(bpy)3 functionalized gold nanoparticles mediated signal transduction
Authors:Manman Dong  Xia LiuQian Dang  Honglan QiQiang Gao  Chengxiao Zhang
Institution:Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi''an, 710062, PR China
Abstract:A novel, sensitive and versatile electrogenerated chemiluminescence biosensing platform is developed for monitoring activity and inhibition of protein kinase based on Ru(bpy)32+ functionalized gold nanoparticles (Ru(bpy)32+-AuNPs) mediated signal transduction. Ru(bpy)32+-AuNPs were formed by functionalizing AuNPs with Ru(bpy)32+ through electrostatic interactions and were used as thiol-versatile signal probe. Casein kinase II (CK2) and cAMP-dependent protein kinase (PKA), two classical protein kinase implicated in disease, were chosen as model protein kinases while a CK2-specific peptide (CRRRADDSDDDDD) and a PKA-specific peptide (CLRRASLG) were employed as molecular substrate for CK2 and PKA, respectively. The specific peptide was self-assembled onto the gold electrode via Au–S bond to form ECL biosensor. Upon thiophosphorylation of the peptide on the electrode in the presence of protein kinase and co-substrate adenosine-5’-(γ-thio)-triphosphate, Ru(bpy)32+-AuNPs was assembled onto the thiophosphorylated peptides via Au–S bond. The Ru(bpy)32+-AuNPs attached on electrode surface produce detectable ECL signal in the presence of coreactant tripropylamine. This strategy is promising for multiple protein kinase assay and kinase inhibitor profiling with high sensitivity, good selectivity and versatility. The ECL intensity is proportional to the activity of CK2 in the range of 0.01–0.5 unit/mL with a low detection limit of 0.008 unit/mL and to the activity of PKA in the range of 0.01–0.4 unit/mL with a detection limit of 0.005 unit/mL. Additionally, this assay was applied to the detection of CK2 in serum samples and the inhibition of CK2 and PKA. This work demonstrates that the developed ECL method can provide a sensitive and versatile platform for the detection of kinase activity and drug-screening.
Keywords:Electrogenerated chemiluminescence  Peptide  Casein kinase II  Protein kinase A  Gold nanoparticles
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号