A practical comparison of surface resistance test electrodes
Institution:1. KOMAG Institute of Mining Technology, Pszczyńska 37, 44-101 Gliwice, Poland;2. Wroclaw University of Science and Technology, Wybrze?e Wyspiańskiego 27, 50-370 Wroclaw, Poland;1. Université de Poitiers (CNRS, ISAE-ENSMA), 86962, Futuroscope, France;2. Toyohashi University of Technology, 7 Toyohashi, 441-8580, Japan
Abstract:Four surface resistance test electrodes are compared using a selection of materials under similar test conditions. The results vary considerably with some materials due to variation in surface resistivity. Using a relatively uniform material two concentric ring electrodes compliant with the same standard differed in results by a factor of 1.8. Silver stripe and copper tape electrodes gave results a factor 0.4 and 0.7 compared to the reference electrode. A 2-pin electrode gave results a factor 4.7 greater. The 2 pin probe cannot be expected to give similar results to the other electrodes for materials that have variable resistivity.
Keywords:Surface resistance  Standard measurement electrodes