首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Spectrophotometric determination of selenium with dithizone
Authors:AD Campbell  AH Yahaya
Institution:Department of Chemistry, University of Otago, DunedinNew Zealand
Abstract:Microgram amounts of selenium(IV) are determined by measuring the decrease in absorbance of dithizone in carbon tetrachloride solution at 620 nm. Relative standard deviations for samples containing 0.20 and 1.00 μg of selenium(IV) are 0.6% and 0.4%, respectively. Of several metals tested only copper (at the 1.0-μg level) and iron (at the 100-μg level) interfere but high concentrations of nitric or perchloric acid cause low results. A reinvestigation of the reaction of selenium(IV) with dithizone suggests a formula Se(HDz)4 for the dithizonate.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏