Palladium and the electrochemical quartz crystal microbalance: a new method for the in situ analysis of the precious metal in aqueous solutions |
| |
Authors: | Carrington Nathan A Rodman D Lynn Xue Zi-Ling |
| |
Affiliation: | Department of Chemistry, The University of Tennessee, Knoxville, TN 37996-1600, United States |
| |
Abstract: | ![]() A new method for the quantitative determination of palladium(II) by the electrochemical quartz crystal microbalance (EQCM) technique has been developed. Using a bare carbon-coated quartz crystal, Pd(II) ions are directly deposited from aqueous solution as palladium metal onto the crystal surface, and the Pd(II) concentration is determined with a detection limit of 0.0156 mM, or 1.66 ppm. No complexing agent or preconcentration of palladium is required for the analysis. The palladium is stripped from the crystal through its electrochemical oxidation, regenerating the crystal for subsequent multi-cycle palladium analyses. A conventional gold-coated quartz crystal was incapable of carrying out the same measurements. The EQCM technique presented is simple, sensitive, and reproducible for the detection of this widely used precious metal. |
| |
Keywords: | Electrochemical quartz crystal microbalance Palladium Carbon-coated quartz crystal Electrochemistry |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|