首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of arsenic at a gold-plated carbon paste electrode using constant current stripping analysis
Authors:Svancara Ivan  Vytras Karel  Bobrowski Andrzej  Kalcher Kurt
Institution:Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Námesti Cs. legii 565, CZ-532 10 Pardubice, Czech Republic.
Abstract:A new stripping method for the determination of arsenic in water samples with a gold film-plated carbon paste electrode has been developed for the use in constant current stripping analysis (CCSA). In the novelized procedure, differentiation between As(III) and chemically pre-reduced As(V), the effect of Cu(II) on the response of arsenic, and the stability of sample solutions were studied in detail. Compared to the voltammetric approach, the method utilizing CCSA offers a more rapid procedure with improved analytical characteristics such as reproducibility, selectivity over the Cu(II) ions, or lower detection limit (3 ppb for As(III) and 0.5 ppb for As(V), respectively). The possibilities of the optimized method are demonstrated by determinations of As(III), As(V), and total arsenic in samples of polluted river water.
Keywords:
本文献已被 PubMed 等数据库收录!