首页 | 本学科首页   官方微博 | 高级检索  
     

Magnetically rotational reactor for absorbing benzene emissions by ionic liquids
引用本文:Yangyang Jiang Chen Guo Huizhou Liu. Magnetically rotational reactor for absorbing benzene emissions by ionic liquids[J]. 中国颗粒学报, 2007, 5(1): 130-133
作者姓名:Yangyang Jiang Chen Guo Huizhou Liu
作者单位:[1]Laboratory of Separation Science and Engineering, National Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100080, China [2]Graduate University of Chinese Academy of Sciences, Beijing 100080, China
摘    要:A magnetically rotational reactor (MRR) has been developed and used in absorbing benzene emissions. The MRR has a permanent magnet core and uses magnetic ionic liquid [bmim]FeCl4 as absorbent. Benzene emissions were carried by N2 into the MRR and were absorbed by the magnetic ionic liquid. The rotation of the permanent magnet core provided impetus for the agitation of the magnetic ionic liquid, enhancing mass transfer and making benzene better dispersed in the absorbent. 0.68 g benzene emissions could be absorbed by a gram of [bmim]FeCl4, 0.27 and 0.40 g/g higher than that by [bmim]PF6 and [bmim]BF4, respectively. The absorption rate increased with increasing rotation rate of the permanent magnet.

关 键 词:磁性离子液体 苯排放 吸附 磁性转动反应器
修稿时间:2006-09-052006-12-01

Magnetically rotational reactor for absorbing benzene emissions by ionic liquids
Yangyang Jiang,Chen Guo,Huizhou Liu. Magnetically rotational reactor for absorbing benzene emissions by ionic liquids[J]. China Particuology, 2007, 5(1): 130-133
Authors:Yangyang Jiang  Chen Guo  Huizhou Liu
Abstract:A magnetically rotational reactor (MRR) has been developed and used in absorbing benzene emissions. The MRR has a permanent magnet core and uses magnetic ionic liquid [bmim]FeCl4 as absorbent. Benzene emissions were carried by N2 into the MRR and were absorbed by the magnetic ionic liquid. The rotation of the permanent magnet core provided impetus for the agitation of the magnetic ionic liquid, enhancing mass transfer and making benzene better dispersed in the absorbent. 0.68 g benzene emissions could be absorbed by a gram of [bmim]FeCl4, 0.27 and 0.40 g/ghigher than that by [bmim]PF6 and [bmim]BF4, respectively. The absorption rate increased with increasing rotation rate of the permanent magnet.
Keywords:Magnetically rotational reactor (MRR)  Magnetic ionic liquid  Absorption  Permanent magnet
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号