首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Practical optical frequency measurement system around 1.5 μm based on an acetylene-stabilized laser-locked optical frequency comb
Authors:Mitsuru Musha  Yosuke Tamura  Ken’ichi Nakagawa  Ken-ichi Ueda
Institution:Institute for Laser Science, University of Electro-Communications, 1-5-1 Chofugaoka, Chofu-shi, Tokyo 182-8585, Japan
Abstract:We have developed a practical and precise frequency measurement system at 1.5 μm telecommunication band. An electro-optic-modulator based optical frequency comb is phase-locked to a dither-free acetylene-stabilized laser to realize an optical frequency comb with frequency uncertainty of 10 kHz (5 × 10−11) and the linewidth of 15 kHz. The present frequency comb can be also used as an optical frequency reference grid defined by ITU-T (International Telecommunication Union, Telecommunication Standardization Sector). Using the present frequency measurement system, we have demonstrated the first optical frequency measurement of 12C16O overtone absorption lines around 1.56 μm with the uncertainty of lower than 900 kHz.
Keywords:07  57  Ty  42  62  Eh  42  62  Fi
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏