首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Simultaneous Determination of Carbamate and Organophosphorus Pesticides in Honeybees by Liquid Chromatography-Mass Spectrometry
Authors:M Fernández  Y Picó  J Mañes
Institution:(1) Laboratori de Bromatologia i Toxicologia, Facultat de Farmàcia, Universitat de València, Av. Vicent Andrés Estellés s/n, 46100 Burjassot, València, Spain
Abstract:Summary The potential of liquid chromatography-mass spectrometry (LC-MS) has been studied for the simultaneous determination of sixteen carbamate and organophosphorus pesticides in honeybees using a traditional sample preparation protocol based on acetone extraction and dichloromethane partitioning. The performances of both atmospheric pressure chemical ionization (APCI) and electrospray (ES) interfaces were compared. APCI offered better sensitivity and specificity for a higher range of pesticides. Limits of quantification were from 0.01 to 0.17 mg kg–1, at which recoveries obtained were between 64 and 93%, except for pirimicarb that was at 13%, with relative standard deviations ranging from 7 to 20%. Fenitrothion, fenoxycarb, methiocarb and phoxim were found in bees from Valencian Community beehives at concentrations between 0.03 and 3.75 mg kg–1.
Keywords:Column liquid chromatography –  mass spectrometry Atmospheric pressure chemical ionization and electrospray ionization Carbamate and organophosphorus pesticides Honeybees
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏