Numerical estimation of mixed convection heat transfer in vertical helically coiled tube heat exchangers
Authors:Hessam Mirgolbabaei  Hessam Taherian  G Domairry  N Ghorbani
Institution:1. Department of Mechanical Engineering, Islamic Azad University, Jouybar Branch, Jouybar, Iran;2. Department of Mechanical Engineering, Babol University of Technology, Babol 47144, Iran;3. Department of Mechanical Engineering, University of Leeds, Leeds, England
Abstract:A numerical investigation of the mixed convection heat transfer from vertical helically coiled tubes in a cylindrical shell at various Reynolds and Rayleigh numbers, various coil‐to‐tube diameter ratios and non‐dimensional coil pitches was carried out. The particular difference in this study compared with other similar studies is the boundary conditions for the helical coil. Most studies focus on constant wall temperature or constant heat flux, whereas in this study it was a fluid‐to‐fluid heat exchanger. The purpose of this article is to assess the influence of the tube diameter, coil pitch and shell‐side mass flow rate on shell‐side heat transfer coefficient of the heat exchanger. Different characteristic lengths were used in the Nusselt number calculations to determine which length best fits the data and finally it has been shown that the normalized length of the shell‐side of the heat exchanger reasonably demonstrates the desired relation. Copyright © 2010 John Wiley & Sons, Ltd.
Keywords:helically coiled tube  heat exchanger  mixed convection  heat transfer  Nusselt number