Temperature's optical tomography diagnosis of arc plasma jet flowing into air |
| |
Authors: | Yun-yun Chen Fang GuGai-ge Zheng Yu-zhu Liu |
| |
Affiliation: | School of Physics and Optoelectronic Engineering, Nanjing University of Information Science and Technology, Nanjing 210044, China |
| |
Abstract: | An argon arc jet plasma flowing into air is chosen as a practical example to study the multiple species jet plasma's optical computerized tomography (OCT) diagnosis. The refractive index models of the pure argon and the multiple species arc plasmas are supplied. On the basis of which, the temperature reconstruction model of the multiple species arc plasma is further derived. By theoretical calculation, the effect of mixed air on the refractive index is given. For the sake of better proving the effect of directly omitting the mixed air on flow field's temperature reconstruction from the refractive index, a simulated experiment is supplied. Finally, the condition, which can be adopted to estimate that whether the pure argon arc plasma refractive index model still can be used as the temperature reconstruction model of the argon arc plasma jet flowing into air, is proposed. |
| |
Keywords: | Jet plasma Multiple species Optical computerized tomography (OCT) Refractive index Temperature reconstruction |
本文献已被 ScienceDirect 等数据库收录! |
|