首页 | 本学科首页   官方微博 | 高级检索  
     


Clinical analysis of human urine by means of potentiometric Electronic tongue
Authors:Larisa Lvova  Eugenio Martinelli  Alberto Bergamini  Corrado Di Natale
Affiliation:a Department of Chemical Science and Technologies, University “Tor Vergata”, 00133 Rome, Italy
b Biological Research Institute of St. Petersburg State University, 198504 St. Petersburg, Russia
c Department of Electronic Engineering, University “Tor Vergata”, 00133 Rome, Italy
d Department of Public Health and Cellular Biology, University “Tor Vergata”, 00133 Rome, Italy
Abstract:The Electronic tongue (ET) composed of different kind of potentiometric chemical sensors has been applied for the detection of urinary system dysfunctions and creatinine levels. The creatinine contents evaluated by ET were compared with those obtained by automated Jaffe’s method and GC-MS, obtaining a satisfying agreement for both methods. Partial least square regression discriminate analysis (PLS-DA) and feed forward back-propagation neural network (FFBP NN) classified 51 urine specimens from healthy volunteers in four classes, according to the creatinine content, showing that both techniques can satisfactorily differentiate urines according to this parameter. The best accuracy result of 92.2% correct classification of unknown samples was achieved with FFBP NN. Moreover, the possibility of ET system to distinguish between urine samples of healthy patients, and those with malignant and non-malignant tumor diagnosis of bladder has been shown.
Keywords:Potentiometric electronic tongue   Urinary system dysfunctions detection   Creatinine analysis
本文献已被 ScienceDirect 等数据库收录!