首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Preconcentration and Determination of Trace Amounts of Heavy Metals in Water Samples Using Membrane Disk and Flame Atomic Absorption Spectrometry
作者姓名:ALI  Moghimi
作者单位:Department of Chemistry, Varamin Campus, Islamic Azad University, Varamin, Iran
摘    要:A fast and simple method for preconcentration of Ni^2+, Cd^2+, Pb^2+, Zn^2+, Cu^2+ and Co^2+ from natural water samples was developed. The metal ions were complexed with sodium diethyldithiocarbamate (Na-DDTC), then adsorbed onto octadecyl silica membrane disk, recovered and determined by FAAS. Extraction efficiency, influence of sample volume and eluent flow rates, effects of pH, amount of Na-DDTC, nature and amount of eluent for elution of metal ions from membrane disk, break through volume and limit of detection have been evaluated. The effect of foreign ions on the percent recovery of heavy metal ions has also been studied. The limit of detection of the proposed method for Ni^2+, Cd^2+, Pb^2+, Zn^2+, Cu^2+ and Co^2+was found to be 2.03, 0.47, 3.13, 0.44, 1.24 and 2.05 ng·mL^-1, respectively. The proposed (DDTC) method has been successfully applied to the recovery and determination of heavy metal ions in different water samples.

关 键 词:水样  痕量重金属  预浓缩  测定  原子吸收光谱
收稿时间:2006-5-23
修稿时间:2006-05-232007-01-15

Preconcentration and Determination of Trace Amounts of Heavy Metals in Water Samples Using Membrane Disk and Flame Atomic Absorption Spectrometry
ALI Moghimi.Preconcentration and Determination of Trace Amounts of Heavy Metals in Water Samples Using Membrane Disk and Flame Atomic Absorption Spectrometry[J].Chinese Journal of Chemistry,2007,25(5):640-644.
Authors:ALI  Moghimi
Institution:[1]Department of Chemistry, Varamin Campus, Islamic Azad University, Varamin, Iran
Abstract:A fast and simple method for preconcentration of Ni2+, Cd2+, Pb2+, Zn2+, Cu2+ and Co2+ from natural water samples was developed. The metal ions were complexed with sodium diethyldithiocarbamate (Na‐DDTC), then adsorbed onto octadecyl silica membrane disk, recovered and determined by FAAS. Extraction efficiency, influence of sample volume and eluent flow rates, effects of pH, amount of Na‐DDTC, nature and amount of eluent for elution of metal ions from membrane disk, break through volume and limit of detection have been evaluated. The effect of foreign ions on the percent recovery of heavy metal ions has also been studied. The limit of detection of the proposed method for Ni2+, Cd2+, Pb2+, Zn2+, Cu2+ and Co2+was found to be 2.03, 0.47, 3.13, 0.44, 1.24 and 2.05 ng·mL?1, respectively. The proposed (DDTC) method has been successfully applied to the recovery and determination of heavy metal ions in different water samples.
Keywords:preconcentration  atomic absorption spectrometry  solid phase extraction  octadecyl bonded silica
本文献已被 维普 等数据库收录!
点击此处可从《中国化学》浏览原始摘要信息
点击此处可从《中国化学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号