Determination of fluorine and chlorine in geological materials by induction furnace pyrohydrolysis and standard-addition ion-selective electrode measurement |
| |
Authors: | Rice T D |
| |
Institution: | Mineral Resources Development Laboratory, New South Wales Department of Mineral Resources, Post Office Box 76, Lidcombe, 2141, Australia. |
| |
Abstract: | Fluorine and chlorine in geological materials are volatilized by pyrohydrolysis at about 1150 degrees in a stream of oxygen (1000 ml/min) plus steam in an induction furnace. The catalyst is a 7:2:1 mixture of silica gel, tungstic oxide and potassium dihydrogen phosphate. The sample/catalyst mixture is pyrohydrolysed in a re-usable alumina crucible (already containing four drops of 1 + 3 phosphoric acid) inserted in a silica-enclosed graphite crucible. The absorption solution is buffered at pH 6.5 and spiked with 1.6 mug of fluoride and 16 mug of chloride per g of solution, to ensure rapid and linear electrode response during subsequent standard-addition measurement. The simple plastic absorption vessel has 99.5% efficiency. The 3s limits of detection are 5-10 mug/g and 40-100 mug/g for fluorine and chlorine respectively. The procedure is unsuitable for determining chlorine in coal. |
| |