Determination of triptolide and triptonide in human plasma by high-performance liquid chromatography |
| |
Authors: | Wang Zhaohong Wen Jiao Xing Junbo Guo Dean |
| |
Affiliation: | The State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Xueyuan Road 38, Beijing 100083, People's Republic of China. |
| |
Abstract: | An isocratic high-performance liquid chromatographic method for determination of triptolide and triptonide in human plasma is described. Plasma samples were extracted with OasisHLB solid-phase extraction (SPE) cartridges. After pretreatment, they were separated on a SymmetryShieldRP(18) column with a mobile phase of acetonitrile-water (40:60,v/v) at 40 degrees C. The effluent was monitored at UV 217 nm. Linearity (0.010-1.0 mg/L) was good, and the lower limit of detection was 3 ng/mL for triptolide and 4.5 ng/mL for triptonide (S/N = 3). The relative standard deviations of intra- and inter-day assay were less than 15% and the recoveries were better than 80%. The developed method was applied to the determination of triptolide and triptonide concentration in a patient's plasma after taking the medicament containing Tripterygium wilfordii Hook. F. |
| |
Keywords: | high performance liquid chromatography solid phase extraction Triptolide Triptonide |
本文献已被 PubMed 等数据库收录! |
|