Abstract: | Due to their high polarity and unique selectivity, cyanopropyl silicones are basic stationary phases for high resolution capillary gas chromatography. Different OH-terminated cyanopropyl silicones, containing a high cyanopropyl content, were synthesized and chromatographically evaluated. Special attention was paid to the degree of immobilization of the phases in FSOT columns. Depending on the problem at hand, a choice has to be made between immobilization and maximum selectivity. |