Selective determination of oxygenates in complex samples with the O-FID analyzer
Authors:G R Verga  A Sironi  W Schneider  J Ch Frohne
Abstract:A gas-chromatographic analyzer allowing the selective detection of individual oxygenates in complex organic mixtures, such as gasolines, is described. The analyzer is based on the oxygen-specific response flame ionization detection (O-FID) method. The system operates with capillary columns and includes a cracking reactor to convert any oxygenate to carbon monoxide and a special FID equipped with a microreactor for the catalytic hydro-genation of CO and detection as methane. Hydrocarbons give no signal. The selectivity of the method is better than 1:107 and the linear range approaches 105. The analysis of modern fuels containing oxygenated additives, to improve octane ratings, may greatly benefit from the proposed analytical method.
Keywords:Capillary gas chromatography  O-FID analyzer  Cracking reactor  Catalytic hydrogenation reactor  Unleaded fuels  Oxygenated additives