首页 | 本学科首页   官方微博 | 高级检索  
     

Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration
引用本文:Jun Ping Xiao,Qing Xiang Zhou,Xiao Ke Tian,Hua Hua Bai,Xian Fa Su Department of Chemistry,University of Science and Technology Beijing,Beijing 100083,China School of Chemistry and Environmental Sciences,Henan Normal University,Henan Key Laboratory for Environmental Pollution Control,Xinxiang 453007,China. Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration[J]. 中国化学快报, 2007, 18(6): 730-733. DOI: 10.1016/j.cclet.2007.04.030
作者姓名:Jun Ping Xiao  Qing Xiang Zhou  Xiao Ke Tian  Hua Hua Bai  Xian Fa Su Department of Chemistry  University of Science and Technology Beijing  Beijing 100083  China School of Chemistry and Environmental Sciences  Henan Normal University  Henan Key Laboratory for Environmental Pollution Control  Xinxiang 453007  China
作者单位:Jun Ping Xiao,Qing Xiang Zhou,Xiao Ke Tian,Hua Hua Bai,Xian Fa Su Department of Chemistry,University of Science and Technology Beijing,Beijing 100083,China School of Chemistry and Environmental Sciences,Henan Normal University,Henan Key Laboratory for Environmental Pollution Control,Xinxiang 453007,China
摘    要:A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail. The experimental results indicated that this method was simple, rapid, and sensitive. The linear range was 8.367×10-4 to 2.789×10-2 mol L-1, the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4-106.9% under the optimal conditions. The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples.

收稿时间:2007-02-26

Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration
Jun Ping Xiao,Qing Xiang Zhou,Xiao Ke Tian,Hua Hua Bai,Xian Fa Su. Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration[J]. Chinese Chemical Letters, 2007, 18(6): 730-733. DOI: 10.1016/j.cclet.2007.04.030
Authors:Jun Ping Xiao  Qing Xiang Zhou  Xiao Ke Tian  Hua Hua Bai  Xian Fa Su
Affiliation:1. Department of Chemistry, University of Science and Technology Beijing, Beijing 100083, China;2. School of Chemistry and Environmental Sciences, Henan Normal University, Henan Key Laboratory for Environmental Pollution Control, Xinxiang 453007, China
Abstract:A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper.Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail.The experimental results indicated that this method was simple, rapid, and sensitive.The linear range was 8.367 x 10-4 to 2.789 x 10-2 mol L-1, the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4-106.9% under the optimal conditions.The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples.
Keywords:Alternating-current oscillopolarographic titration  Aniline  Potassium bromide
本文献已被 CNKI 万方数据 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号