首页 | 本学科首页   官方微博 | 高级检索  
     


Local Nusselt number and temperature field in turbulent flow through a heated square-sectioned U-bend
Authors:R.W. Johnson  B.R. Launder
Affiliation:1. Mechanical Engineering Department, Thermodynamics and Fluid Mechanics Division, UMIST, PO Box 88, Manchester M60 1QD, UK
Abstract:Local heat transfer coefficients and temperature distributions within the fluid for air flow around a 180° square-sectioned bend have been measured. The ratio of bend radius to hydraulic diameter of the duct is 3.35:1 and the flow entering the bend is sensibly fully developed. Measurements of air and wall temperatures span a range of Reynolds numbers from 9.9 × 103 to 9.2 × 104 with the principal emphasis given to the case of Re ? 5.6 × 104. This Reynolds number and geometric configuration coincide with that of a companion LDA study carried out by Chang et al1 which provides detailed maps of the mean and turbulent velocity fields. The data show that by 45° into the bend the heat transfer coefficients on the inner convex wall of the bend drop markedly while those on the other walls increase. By 90° the ratio of the heat transfer coefficients at the mid positions of the concave and convex walls is more than 2:1. Nevertheless this ratio is less than would be anticipated from considering two-dimensional flow on weakly curved surfaces. There is a general consistency between the velocity and the temperatyre field data in the heated fluid
Keywords:turbulence  ducting  heat transfer  convection
本文献已被 ScienceDirect 等数据库收录!