Rapid collection of iron hydroxide for determination of Th isotopes in seawater |
| |
Authors: | Ayako Okubo Hajime Obata Masaaki Magara Takaumi Kimura Hiroshi Ogawa |
| |
Affiliation: | 1. Japan Atomic Energy Agency, Research Group for Analytical Chemistry, Japan;2. Atmosphere Ocean Research Institute, The University of Tokyo, Japan |
| |
Abstract: | ![]() This work introduces a novel method of recovery of iron hydroxide using a DIAION CR-20 chelating resin column to determine Th isotopes in seawater with a sector field (SF) inductively coupled plasma mass spectrometer (ICP-MS). Thorium isotopes in seawater were co-precipitated with iron hydroxide, and this precipitate was sent to chelating resin column. Ferric ions in the iron hydroxide were bonded to functional groups of the chelating resin directly, resulting in a pH increase of the effluent by release of hydroxide ion from the iron hydroxide. The co-precipitated thorium isotopes were quantitatively collected within the column, which indicated that thorium was retained on the iron hydroxide remaining on the chelating column. The chelating column quantitatively collected 232Th with iron hydroxide in seawater at flow rates of 20–25 mL min−1. Based on this flow rate, a 5 L sample was processed within 3–4 h. The >20 h aging of iron hydroxide tends to reduce the recovery of 232Th. The rapid collection method was successfully applied to the determination of 230Th and 232Th in open-ocean seawater samples. |
| |
Keywords: | Thorium isotopes Seawater Iron hydroxides co-precipitation Chelating resin |
本文献已被 ScienceDirect 等数据库收录! |