A POLAROGRAPHIC CATHODIC WAVE OF VITAMIN C |
| |
作者单位: | Shu Bo HAN Zhuo Bin YUAN Department of Chemistry,Graduate School,USTC,Academia Sinica,Beijing 100039,P.R.China Present Address:Dept.of Environ.Eng.,Hebei Light & Chemical Institute,Shijiazhuang 050018,Hebei,P.R.C. |
| |
摘 要: | The cathodic wave of vitamin C has not been reported in the literature so far.Its E_(1/2)wasfound at-1.85 volt vs.Ag/AgCl(25℃)in the base solution of 0.1mol/L Bu_4NI.Variouselectrochemical and spectral techniques were used for studying the electrode reaction.They all showed that the electrode reaction was quasi-reversible while C was more than1.0×10~(-6)mol/L and mainly adsorptive while C was less than 1.0×10~(-6)mol/L at a mercuryelectrode.The electron transfer number was 2 and the electron transfer coefficient 0.57.Using DPP techniques,the linear response range was 5.0×10~(-7)-2.0×10~(-3)mol/L and thedetection limit 1×10~(-7)mol/L.
|
A POLAROGRAPHIC CATHODIC WAVE OF VITAMIN C |
| |
Authors: | Shu Bo HAN Zhuo Bin YUAN |
| |
Institution: | Shu Bo HAN Zhuo Bin YUAN Department of Chemistry,Graduate School,USTC,Academia Sinica,Beijing 100039,P.R.China Present Address:Dept.of Environ.Eng.,Hebei Light & Chemical Institute,Shijiazhuang 050018,Hebei,P.R.C. |
| |
Abstract: | |
| |
Keywords: | vitamin C DPP Polarographic cathodic wave |
本文献已被 CNKI 等数据库收录! |