首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of Triazines and N-Methylcarbamate Pesticides in Water by High-Performance Liquid Chromatography-Diode Array Detection
Authors:Sibel Topuz  Buket Alpertunga
Institution:Department of Pharmaceutical Toxicology Faculty of Pharmacy , Istanbul University , Istanbul, 34116, Turkey
Abstract:

A rapid and selective method for the simultaneous determination of triazine herbicides (atrazine, its degradation product desethylatrazine, simazine, prometryn, terbutryn) and N-methylcarbamate insecticides (propoxur, carbaryl and methiocarb) in surface water has been developed. A 0.5 L of the water sample was preconcentrated by passage through a 1 g C18 solid-phase extraction cartridge. The retained compounds were eluted with 5 mL of methanol from the cartridge. The pesticides were separated and quantified by reversed-phase high-performance liquid chromatography with UV diode-array detection. Analytical separation was performed using a concave gradient elution with acetonitrile and water on a C18 column. Prometryn and terbutryn were determined at 240 nm; propoxur, methiocarb at 204 nm and the others at 220 nm. Recoveries varied from 85 to 102% over concentrations at 0.025 and 0.2 µg L?1. The limits of detection for the compounds investigated are in the range of 0.005-0.012 µg L?1.
Keywords:High-performance Liquid Chromatography  Diode-array Detection  Water Analysis  Pesticides  N-methylcarbamates  Triazines
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号