首页 | 本学科首页   官方微博 | 高级检索  
     检索      

采用氧合血红蛋白吸收带的漫反射光谱比率R(540)/R(575)检测浅表性膀胱癌
引用本文:魏华江,邢达,巫国勇,鲁建军,吴荣海,谷怀民,何博华,陈雪梅.采用氧合血红蛋白吸收带的漫反射光谱比率R(540)/R(575)检测浅表性膀胱癌[J].光谱学与光谱分析,2008,28(11).
作者姓名:魏华江  邢达  巫国勇  鲁建军  吴荣海  谷怀民  何博华  陈雪梅
作者单位:1. 华南师范大学激光生命科学研究所,暨激光生命科学教育部重点实验室,广东,广州,510631
2. 中山大学第一附属医院心胸外科,广东,广州,510080
3. 广东省江门市中心医院泌尿外科,广东,江门,529071
4. 广东药学院临床医学系外科,广东,广州,510224
5. 中山大学第一附属医院眼科,广东,广州,510080
基金项目:国家自然科学基金 , 广东省自然科学基金  
摘    要:采用氧合血红蛋白在540和575 nm吸收带的漫反射光谱比率(R540/R575)对人浅表性膀胱癌进行了鉴别诊断,实验采用带积分球附件的分光光度计获取组织的漫反射光谱。结果表明:正常膀胱的粘膜/粘膜下层组织的漫反射光谱比率(R540/R575)在组织离体后2 h的平均值为111%,3 h的平均值为107%,4 h的平均值为104%,5 h的平均值为102%,而浅表性的膀胱癌的粘膜/粘膜下层组织的漫反射光谱比率(R540/R575)在组织离体后2 h的平均值为98.4%,3 h的平均值为95.5%,4 h的平均值为93.1%,5 h的平均值为91.6%,正常膀胱与浅表性膀胱癌的粘膜/粘膜下层组织在组织离体后2,3,4和5 h的漫反射光谱比率(R540/R575)均有显著性的差异(p<0.05),分别为12.6%,11.5%,10.9%和10.4%。这结论为快速、低成本、非入侵的浅表性膀胱癌的光活检提供了一种新的方法。

关 键 词:浅表性膀胱癌诊断  漫反射光谱  漫反射光谱比率(R540/R575)  血红蛋白吸收峰

Superficial Bladder Cancer Detection Using Diffuse Reflectance Spectral Ratio R540/R575 of Oxygenated Hemoglobin Bands
WEI Hua-jiang,XIANG Da,WU Guo-yong,LU Jian-jun,WU Rong-hai,GU Huai-min,HE Bo-hua,CHEN Xue-mei.Superficial Bladder Cancer Detection Using Diffuse Reflectance Spectral Ratio R540/R575 of Oxygenated Hemoglobin Bands[J].Spectroscopy and Spectral Analysis,2008,28(11).
Authors:WEI Hua-jiang  XIANG Da  WU Guo-yong  LU Jian-jun  WU Rong-hai  GU Huai-min  HE Bo-hua  CHEN Xue-mei
Abstract:A low-cost,fast,and noninvasive method for early diagnosis of malignant lesions of mucosa tissue based on diffuse reflectance spectra was applied in the study of the optical biopsy of superficial human bladder cancer.In the present paper,differential diagnosis of superficial human bladder cancer was studied using the diffuse reflectance spectral ratio(R540/R575) of the oxygenated hemoglobin absorption bands at 540 and 575 nm in vitro.Diffuse reflectance spectra for mucosa/submucosa tissues of normal bladder and superficial bladder cancer were measured using a spectrophotometer with an integrating sphere attachment.The results of measurement showed that there were three the diffuse reflectance spectral dips at 415,542 and 577 nm respectively for mucosa/submucosa tissues of normal bladder and superficial bladder cancer in the spectral range from 400 to 600 nm.The mean diffuse reflectance spectral ratio(R540/R575) of normal bladder mucosa/submucosa tissue decreased slowly with time increase after surgical excision,and the mean diffuse reflectance spectral ratio(R540/R575) of superficial bladder cancer mucosa/submucosa tissue also decreased slowly with time increasing after surgical excision.The mean diffuse reflectance spectral ratios(R540/R575) of normal bladder mucosa/submucosa tissue were 111%,107%,104% and 102% after 2,3,4 and 5 h after surgical excision respectively,and those of superficial bladder cancer mucosa/submucosa tissue were 98.4%,95.5%,93.1% and 91.6% after 2,3,4 and 5 h after surgical excision respectively.There were significant differences in mean diffuse reflectance spectral ratio(R540/R575) for mucosa/submucosa tissues between normal bladder and superficial bladder cancer after 2,3,4 and 5 h after surgical excision respectively(p<0.05).Differences in mean diffuse reflectance spectral ratio(R540/R575) for mucosa/submucosa tissues between normal bladder and superficial bladder cancer were 12.6%,11.5%,10.9% and 10.4% after 2,3,4 and 5 h after surgical excision respectively.It is obvious that pathological changes in bladder mucosa/submucosa tissues induced changes in the component and structure of the tissues,and especially quantitative changes in oxyhemoglobin and de-oxyhemoglobin of tissues obviously.Conclusion of the study provides a new method that can be applied to rapid,low-cost and noninvasive optical biopsy of superficial bladder cancer.
Keywords:Superficial bladder cancer diagnosis  Diffuse reflectance spectroscopy  Diffuse reflectance spectral ratio(R540/R575)  Hemoglobin absorption peaks
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号