首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于酶催化沉积质量放大的压电免疫传感器的研究
引用本文:符婷,王桦,沈国励,俞汝勤.基于酶催化沉积质量放大的压电免疫传感器的研究[J].高等学校化学学报,2006,27(6):1032-1035.
作者姓名:符婷  王桦  沈国励  俞汝勤
作者单位:湖南大学化学化工学院,化学/生物传感与计量学国家重点实验室,长沙,410082;湖南大学化学化工学院,化学/生物传感与计量学国家重点实验室,长沙,410082;湖南大学化学化工学院,化学/生物传感与计量学国家重点实验室,长沙,410082;湖南大学化学化工学院,化学/生物传感与计量学国家重点实验室,长沙,410082
基金项目:国家高技术研究发展计划(863计划)
摘    要:提出了一种酶催化沉积质量放大的高灵敏压电免疫传感器. 采用1,6-二巯基己烷在石英晶振上自组装一单分子层, 再通过另一端巯基连接胶体金, 利用胶体金的高比表面积和强吸附作用力增加抗IgG抗体的固定量, 同时借助胶体金优良的生物亲和性保持抗IgG抗体的活性. 在H2O2存在下, 通过标记在抗人IgG抗体上的HRP酶催化底物DAB(3,3′-联苯二胺), 反应中生成的不溶性产物沉积到石英晶振的Au电极表面, 达到质量放大的目的. 结果表明, 检测人IgG在16 ng/mL-100 μg/mL范围内有很好的线性关系, 检测下限为10 ng/mL, 在用于实际试样的回收率测定中, 结果良好.

关 键 词:酶催化放大  胶体金  1  6-二巯基自组装  压电免疫传感器
文章编号:0251-0790(2006)06-1032-04
收稿时间:09 23 2005 12:00AM
修稿时间:2005-09-23

An Amplified Piezoelectric Immunosensor Based on Amplification of Enzyme-catalyzed Precipitation Mass
FU Ting,WANG Hua,SHEN Guo-Li,YU Ru-Qin.An Amplified Piezoelectric Immunosensor Based on Amplification of Enzyme-catalyzed Precipitation Mass[J].Chemical Research In Chinese Universities,2006,27(6):1032-1035.
Authors:FU Ting  WANG Hua  SHEN Guo-Li  YU Ru-Qin
Institution:State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
Abstract:In this paper, an amplified immunosensor with highly sensitivity has been proposed based on precipitation of an insoluble product on functionalized electrode. Anti-hIgG was immobilized onto the surface of gold electrode modified with 1,6-hexanedithiol and colloidal Au interface. It was proved that the amount of immobilized antibody and the immunoactivity of bound antibodies could be well improved by colloidal Au. HRP labeled antibody reacted with antigen, then HRP biocatalyzed DAB (3,3′-diaminobenzidine) in the presence of H2O2, resulting in an insoluble product on the electrode surface, to achieve an obviously decreased frequency. Comparing with the direct detection of antigens, the immunosensor with the proposed amplified procedure shows improved sensitivity due to the significantly extended detection range. Analytical results indicate that the developed amplified procedure is a promising alternative for biorecognition element on the electrode surface showing an improved performance in terms of the magnitude of the response and sensitivity. The proposed immunosensor in optimal conditions has a linear range of 16 ng/mL-100 μg/mL for hIgG detection with a detection limit of 10 ng/mL. The immunosensor can be used to quantitatively determine hIgG in the sample of human serum.
Keywords:Enzyme-biocatalyzed amplification  Colloidal Au  1  6-Hexanedithiol self-assemble  Piezoelectric immunosensor
本文献已被 CNKI 维普 万方数据 等数据库收录!