首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于D型双芯PCF的近红外宽检测范围SPR折射率传感器
引用本文:张瑾,常敏,陈楠,刘学静,章曦,杜嘉,丁鑫.基于D型双芯PCF的近红外宽检测范围SPR折射率传感器[J].光学技术,2022,48(1):109-115.
作者姓名:张瑾  常敏  陈楠  刘学静  章曦  杜嘉  丁鑫
作者单位:上海理工大学光电信息与计算机工程学院医用光学技术与仪器教育部重点实验室,上海200093
基金项目:“国家质量基础设施体系”重点专项(2021YFF0600902)。
摘    要:现有报道的PCF-SPR折射率传感器的检测范围普遍较窄,不能实现低折射率的检测,且工作波段多数集中在可见光或通信波段,这限制了传感器的应用范围.鉴于此,提出了一种基于D型双芯PCF结构的SPR传感器,使用氧化铟锡作为等离子体材料沉积在D型PCF抛光表面,并对该传感器的理论模型进行了分析,包括金属参数对传感性能的影响,P...

关 键 词:光子晶体光纤  表面等离子体共振  有限元法  折射率传感器

Surface plasmon resonance sensor based on D-shaped Dual-core photonic crystal fiber for wide refractive index detection range in Near-infrared spectrum
Zhang Jin,Chang min,Chen Nan,Liu XueJing,Zhang Xi,Du Jia,Ding Xin.Surface plasmon resonance sensor based on D-shaped Dual-core photonic crystal fiber for wide refractive index detection range in Near-infrared spectrum[J].Optical Technique,2022,48(1):109-115.
Authors:Zhang Jin  Chang min  Chen Nan  Liu XueJing  Zhang Xi  Du Jia  Ding Xin
Institution:(Key Lab of Medical Optical Technology and Instruments Ministry of Education,School of Optical-electronic and Computer Engineering,University of Shanghai for Science and Technology,Shanghai 200093,China)
Abstract:The detection range of the PCF-SPR refractive index sensor reported in the past is generally narrow,and the detection of low refractive index cannot be realized,and the wavelength is mostly concentrated in the visible waveband or communication waveband,which limits the application range of the sensor.In view of this,an SPR sensor based on D-shaped dual core PCF structure is proposed.Indium tin oxide is deposited on the polished surface of D-shaped PCF as plasma material,and the theoretical model of the sensor is analyzed,including the influence of metal parameters on sensing performance and the influence of PCF structure parameters on sensing performance.The results show that the sensor can achieve an ultra-wide detection range with a refractive index of 1.27~1.39.Its working wavelength is in the near-infrared region of 1300~2600 nm,the highest sensitivity can reach 35000 nm/RIU,the resolution is 2.85×10-6RIU.The ultra-high sensitivity and ultra-wide refractive index detection range of the sensor can be applied to the detection of plasma,white blood cellsWBC],HemoglobinHb],intestinal mucosa of huma,human liver,acetone and other biological tissues,as well as in the fields of medicine and chemistry.
Keywords:photonic crystal fiber  surface plasmon resonance  finite element method  refractive index sensor
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号