首页 | 本学科首页   官方微博 | 高级检索  
     检索      


As, Cd, Cr, Ni and Pb pressurized liquid extraction with acetic acid from marine sediment and soil samples
Authors:Jorge Moreda-Pieiro  Elia Alonso-Rodríguez  Purificacin Lpez-Mahía  Soledad Muniategui-Lorenzo  Darío Prada-Rodríguez  Antonio Moreda-Pieiro  Adela Bermejo-Barrera  Pilar Bermejo-Barrera
Institution:

aDepartment of Analytical Chemistry, Faculty of Sciences, University of A Coruña. Campus da Zapateira s/n. E-15071. A Coruña, Spain

bUniversity Institute of Environment, University of A Coruña, Pazo de Lóngora, Liáns, E-15179. Oleiros, Spain

cDepartment of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, University of Santiago de Compostela, Avenida das Ciencias, s/n. E-15782, Santiago de Compostela, Spain

Abstract:Rapid leaching procedures by Pressurized Liquid Extraction (PLE) have been developed for As, Cd, Cr, Ni and Pb leaching from environmental matrices (marine sediment and soil samples). The Pressurized Liquid Extraction is completed after 16 min. The released elements by acetic acid Pressurized Liquid Extraction have been evaluated by inductively coupled plasma-optical emission spectrometry. The optimum multi-element leaching conditions when using 5.0 ml stainless steel extraction cells, were: acetic acid concentration 8.0 M, extraction temperature 100 °C, pressure 1500 psi, static time 5 min, flush solvent 60%, two extraction steps and 0.50 g of diatomaceous earth as dispersing agent (diatomaceous earth mass/sample mass ratio of 2). Results have showed that high acetic acid concentrations and high extraction temperatures increase the metal leaching efficiency. Limits of detection (between 0.12 and 0.5 μg g? 1) and repeatability of the over-all procedure (around 6.0%) were assessed. Finally, accuracy was studied by analyzing PACS-2 (marine sediment), GBW-07409 (soil), IRANT-12-1-07 (cambisol soil) and IRANT-12-1-08 (luvisol soil) certified reference materials (CRMs). These certified reference materials offer certified concentrations ranges between 2.9 and 26.2 μg g? 1 for As, from 0.068 to 2.85 μg g? 1 for Cd, between 26.4 and 90.7 μg g? 1 for Cr, from 9.3 to 40.0 μg g? 1 for Ni and between 16.3 and 183.0 μg g? 1 for Pb. Recoveries after analysis were between 95.7 and 105.1% for As, 96.2% for Cd, 95.2 and 100.6% for Cr, 95.7 and 103% for Ni and 94.2 and 105.5% for Pb.
Keywords:PLE  Acetic acid  Metals  Environmental matrix  ICP-OES
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号