首页 | 本学科首页   官方微博 | 高级检索  
     


Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the estimation of nicorandil in human plasma
Authors:Bhatt Jignesh  Jangid Arvind  Shah Bhavin  Shetty Raghavendra  Kambli Sandeep  Subbaiah Gunta  Singh Sadhana
Affiliation:Torrent Research Centre, Gandhinagar-382428, Gujarat, India. jigu_baruda@rediffmail.com
Abstract:
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of nicorandil in human plasma. Nicorandil was extracted from human plasma using solid-phase extraction technique. Imipramine was used as the internal standard. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection at nanogram levels. The proposed method has been validated for a linear range of 1.0-500.0 ng/mL with a correlation coefficient of > or =0.9993. The intra-run and inter-run precision and accuracy was within 10.0%. The overall recovery for nicorandil was 63.81%. The total run time was just 3.0 min.
Keywords:nicorandil  LC‐MS/MS  human plasma
本文献已被 PubMed 等数据库收录!