首页 | 本学科首页   官方微博 | 高级检索  
     


A study of some parameters relevant to the response of harwell PMMA dosimeters to gamma and electron irradiation
Authors:KM Glover   ME Plested   MF Watts  B Whittaker
Affiliation:

Process Services Division, AEA Technology, Harwell Laboratory, Oxfordshire, OX11 ORA, United Kingdom

Abstract:
The effects on the radiation response of Harwell polymethylmethacrylate (PMMA) dosimeters of dose-rate, radiation type, temperature during irradiation and post-irradiation storage, and post-irradiation stability, are of importance to the operators of commercial irradiation facilities.

This paper describes recent studies of the effects of some of these parameters on the radiation response of Harwell Red 4034, Amber 3042, and Gammachrome YR Perspex dosimeters, and provides data on batch to batch variation and shelf-life.

Keywords:PMMA dosimeters   dosimeter response   electron beam   Co-60 gamma   irradiation   dose-rate   temperature   shelf-life
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号