首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of fluoride in plant material with a ione-selective electrode
Authors:Berit Eyde
Institution:(1) Chemical Analytical Laboratory, Agricultural University of Norway, Box 31, 1432 Ås-NLH, Norway
Abstract:Summary A method is described for determination of totalfluoride in plant material using the Orion fluorideselective electrode. Dried and ground samples are fused in nickel crucibles with sodium hydroxide. To the melt is added water, dil. hydrochloric acid and citrate buffer solution. The filtered solution are then measured with the electrode. The investigation also includes a study of the influence of ionic strength, pH, and interfering ions as iron and aluminium. The effect of storage of dissolved samples in glass and polyethylen bottles has also been studied. With more than about 0.4 ppm of F standard deviation is about 4–5%. With 0.1 ppm it is 20%.
Fluoridbestimmung in Pflanzenmaterial mit Hilfe der ionenselektiven Elektrode
Zusammenfassung Zur Bestimmung wird die fluorid-selektive Orion-Elektrode verwendet. Die getrockneten und gemahlenen Proben werden im Nickeltiegel mit NaOH geschmolzen und durch Zugabe von Wasser, verd. HCl und Citratpuffer und anschließende Filtration die Meßlösung erhalten. Der Einfluß von Ionenstärke, pH, Fremdionen (Fe, Al), sowie der Lagerung in Glas und Polyethylenflaschen wurde untersucht. Bei mehr als 0,4 ppm F beträgt die Standardabweichung 4–5%, bei 0,1 ppm etwa 20%
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号