Contrast-enhanced 3D MR voiding urethrography: preliminary results
Authors:Yekeler Ensar  Suleyman Erdogan  Tunaci Atadan  Tunaci Mehtap  Balci Numan Cem  Onem Kadir  Tunc Murat  Acunas Gulden
Institution:Department of Radiology, Istanbul Faculty of Medicine, Istanbul University, Capa, Istanbul, Turkey.
Abstract:Contrast-enhanced 3D MR voiding urethrography (CE 3D MRVU) was performed on 5 healthy volunteers and 18 patients with urethral disease. After intravenous injection of 0.3 ml/kg gadolinium, the images of the three consecutive acquisitions of the 3D MRVU technique were obtained during voiding. The raw data were reconstructed on all patients for visual analysis. The image quality of the volunteers was technically sufficient to demonstrate normal urethral anatomy. Contrast-enhanced 3D MR voiding urethrography of the urethral strictures was compared with conventional retrograde urethrography (n = 10) and urethroscopy (n = 12). The urethral pathologies including strictures and other obstructive causes of impaired urethral flow were correctly identified on CE 3D MRVU.