Continuous separation of microparticles by size with direct current-dielectrophoresis |
| |
Authors: | Kang Kwan Hyoung Kang Yuejun Xuan Xiangchun Li Dongqing |
| |
Institution: | Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada. |
| |
Abstract: | Direct current-dielectrophoresis (DC-DEP), the induced motion of the dielectric particles in a spatially nonuniform DC electric field, is demonstrated to be a highly efficient method to separate the microparticles by size. The locally nonuniform electric field is generated by an insulating block fabricated inside a polydimethylsiloxane microchannel. The particle experiences a negative DEP (accordingly a repulsive force) at the corners of the block, where the local electric-field strength is the strongest. Thus, the particle deviates from the streamline and the degree of deviation is dependent on the DEP force (i.e., the particle size). Combined with the electrokinetic flow, mixed polystyrene particles of a few micrometers difference in diameter can be continuously separated into distinct reservoirs. For separating target particles of a specific size, it is required to simply adjust the voltage outputs of the electrodes. A numerical model based on the Lagrangian tracking method is developed to simulate the particle motion and the results showed a reasonable agreement with the experimental data. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|