首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Quantitative determination of selected compounds in a Kentucky 1R4F reference cigarette smoke by multidimensional gas chromatography and selected ion monitoring-mass spectrometry
Authors:E L White  M S Uhrig  T J Johnson  B M Gordon  R D Hicks  M F Borgerding  W M Coleman  J F Elder
Institution:R.J. Reynolds Tobacco Company, Bowman Gray Technical Center, Winston-Salem, North Carolina 27102.
Abstract:Eight compounds from a Kentucky 1R4F reference cigarette smoke condensate have been determined by selected ion monitoring-mass spectrometry (SIM-MS) to confirm the validity of multidimensional gas chromatography (MDGC) as a quantitative tool in complex mixture analyses. Four electrostatically precipitated smoke condensate samples of 100 cigarettes each are dissolved individually in 25 mL of 2-propanol. The 2-propanol contains two methyl esters (C8 and C14) and seven deuterium-labeled compounds used as internal standards (IS). Analysis of the compounds of interest, pyridine; acetamide; acrylamide; phenol; o-, m-, and p-cresol; and quinoline, is accomplished by using two heartcuts. Heartcut times of the MDGC analysis are selected such that at least one IS is transferred with each group of compounds being analyzed. This study shows that the MDGC technique previously developed and described can be used for quantitative analyses. A comparison is made between the two types of internal standards. The results obtained for both types of internal standards agree within 20% of each other, on the average, with higher standard deviations for approximately 60% of the compounds where methyl esters are used as internal standards.