X-ray fluorescence method for the determination of rare earths, uranium and thorium in allanites |
| |
Authors: | V. P. Bellary S. S. Deshpande R. M. Dixit A. V. Sankaran |
| |
Affiliation: | (1) Spectroscopy Div., Bhabha Atomic Res. Centre, 400085 Trombay, Bombay, India |
| |
Abstract: | Summary An X-ray fluorescence (XRF) method for the determination of La, Ce, Pr, Nd, Sm, Gd, Th and U in allanites is described. The estimation limits for different impurity elements are La 0.5–10%, Ce 2–20%, Pr 0.1–2.0%, Nd 0.5–10%, Sm 0.1–2%, Gd 0.1–2.0%, Th 0.2–4% and U 0.2–4%. The sample is diluted in the ratio of 19 by boric acid and double layer pellets are prepared. The precision of the method which varies from 0.2–15% has been determined for every element in each standard. Accuracy of the method is assessed by comparison of the values for rare earth, thorium and uranium content with those obtained by optical emission spectroscopic method and the values for uranium and thorium with those obtained by neutron activation analysis.
Röntgenfluorescenzmethode zur Bestimmung von Seltenen Erden, Uran und Thorium in Allaniten Zusammenfassung Das beschriebene Verfahren eignet sich zur Bestimmung von La, Ce, Pr, Nd, Sm Gd, Th und U in Allaniten. Die Bestimmungsgrenzen für die einzelnen Elemente betragen: La 0,5–10%; Ce 2–20%; Pr 0,1–2%; Nd 0,5–10%; Sm 0,1–2%; Gd 0,1–2%; Th 0,2–4%; U 0,2–4%. Die Probe wird mit Borsäure im Verhältnis 19 vermischt und zu Doppelschicht-Tabletten gepreßt. Die Reproduzierbarkeit beträgt 0,2–15% und wurde für jedes Element im jeweiligen Standard bestimmt. Die Richtigkeit des Verfahrens wurde durch Vergleich mit Ergebnissen der Emissionsspektralanalyse (SE, U) sowie der Neutronenaktivierungsanalyse (U, Th) beurteilt. |
| |
Keywords: | Best. von Seltenen Erden, Thorium, Uran in Allanit Rö ntgenfluorescenz-Spektrometrie |
本文献已被 SpringerLink 等数据库收录! |
|