首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Voltammetric Determination of Captopril on a Glassy Carbon Electrode Modified with Copper Metal‐organic Framework
Abstract:We report in this work, a new method for the determination of captopril by differential pulse voltammetry using a glassy carbon electrode modified with a copper metal‐organic framework (H‐Kust‐1 or Cu3(BTC)2 or Cu‐BTC), immobilized on the surface by a copolymer of acrylamide and sodium acrylate. This compound is detected by the formation of a copper(II)‐captopril complex that is observed in an oxidation potential at ca. +0.28 V vs . Ag/AgCl. A linear dynamic range is obtained for a captopril concentration of 0.5 μM to 7.0 μM and the voltammetric response is highly reproducible within 3.52 % error. The sensitivity of 9.71±0.37 nA μM−1 and the limit of detection of 0.20±0.01 μM make this methodology highly applicable for practical applications. The determination of captopril in a commercial pharmaceutical sample showed a recovery of 93.3 %.
Keywords:Copper metal-organic framework  H Kust-1 or Cu3(BTC)2 or Cu-BTC  Captopril  Acrylamide and sodium acrylate copolymer  Differential pulse voltammetry
设为首页 | 免责声明 | 关于勤云 | 加入收藏