首页 | 本学科首页   官方微博 | 高级检索  
     检索      


CHOICE OF COATINGS FOR THE OPTICAL ELEMENTS IN THE IRRADIATION SYSTEM OF VACUUM-ULTRAVIOLET RADIATION ABOVE 50 nm
Authors:Kotaro  Hidea  Hiroshi  Maezawa  Atsushi  Ito  Katsumi  Kobayashi  Yoshiya  Furusawa Takashi  Ito
Institution:Biophysics Laboratory, Rikkyo University, Nishi-ikebukuro 3, Toshima-ku Tokyo 171, Japan;Department of Radiology, School of Medicine, Tokai University, Boseidai, Isehara, Kanagawa 259-11, Japan;Institute of Physics, College of Arts and Sciences, University of Tokyo, Komaba 3-8-1, Meguro-ku, Tokyo 153, Japan;Department of Biological Sciences, University of Tsukuba, Sakuramura, Ibaraki 305, Japan;Department of Molecular Biology, School of Medicine, Tokai University, Boseidai, Isehara, Kanagawa 259-11, Japan
Abstract:The spectral throughput of a vacuum-ultraviolet irradiation system at the SOR-RING facility was examined with various combinations of aluminum-and gold-coated optical elements in a 2.2-m modified Wadsworth monochromator. We found that the optimum was a combination of an aluminum-coated collimating mirror, concave grating, and plane deflecting mirror, and a combination of a gold-coated collimating mirror, concave grating and an aluminum-coated plane deflecting mirror in the wavelength regions 190-110 nm and 110-50 nm, respectively.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号