Abstract: | An ion chromatographic method is described for the purpose of quality control in the process of monochloroacetic acid production. Using 2.5 mM NaOH–10% methanol as eluent, the simultaneous determination of acetic acid, monochloroacetic acid, dichloroacetic acid, and Cl− was obtained in a single run. Monochloroacetic acid and dichloroacetic acid showed good linearity in the range 0.1–20 and 0.15–20 μg/ml and correlation coefficients were 0.9999 and 0.9998, respectively. The detection limits (signal-to-noise ratio 3:1) of monochloroacetic acid and dichloroacetic acid were 17 and 25 ng/ml. This simple, sensitive, and time-saving method can be applied for composition analysis in acetic acid chlorination production. |
| |