Fast quantitation of 5-hydroxymethylfurfural in honey using planar chromatography
Authors:Chernetsova Elena S  Revelsky Igor A  Morlock Gertrud E
Institution:(1) Institute of Food Chemistry, University of Hohenheim, Garbenstrasse 28, 70599 Stuttgart, Germany;(2) On leave from National Research Center “Kurchatov Institute”, Akademika Kurchatova sq. 1, 123182 Moscow, Russia;(3) On leave from People’s Friendship University of Russia, Miklukho-Maklaya st. 6, 117198 Moscow, Russia;(4) Chemistry Department, Lomonosov Moscow State University, Leninskie Gory 1 bldg. 3, GSP-2, 119991 Moscow, Russia
Abstract:An approach for rapid quantitation of 5-hydroxymethylfurfural (HMF) in honey using planar chromatography is suggested for the first time. In high-performance thin-layer chromatography (HPTLC) the migration time is approximately 5 min. Detection is performed by absorbance measurement at 290 nm. Polynomial calibration in the matrix over a range of 1:80 showed correlation coefficients, r, of ≥ 0.9997 for peak areas and ≥ 0.9996 for peak heights. Repeatability in the matrix confirmed the suitability of HPTLC–UV for quantitation of HMF in honey. The relative standard deviation (RSD, %, n = 6) of HMF at 10 ng/band was 2.9% (peak height) and 5.2% (peak area); it was 0.6% and 1.0%, respectively, at 100 ng/band. Other possible detection modes, for example fluorescence measurement after post-chromatographic derivatization and mass spectrometric detection, were also evaluated and can coupling can be used as an additional tool when it is necessary to confirm the results of prior quantitation by HPTLC–UV. The confirmation is provided by monitoring the HMF sodium adduct M + Na]+ at m/z 149 followed by quantitation in TIC or SIM mode. Detection limits for HPTLC–UV, HPTLC–MS (TIC), and HPTLC–MS (SIM) were 0.8 ng/band, 4 ng/band, and 0.9 ng/band, respectively. If 12 μL honey solution was applied to an HPTLC plate, the respective detection limits for HMF in honey corresponded to 0.6 mg kg−1. Thus, the developed method was highly suitable for quantitation of HMF in honey at the strictest regulated level of 15 mg kg−1. Comparison of HPTLC–UV detection with HPTLC–MS showed findings were comparable, with a mean deviation of 5.1 mg kg−1 for quantitation in SIM mode and 6.1 mg kg−1 for quantitation in TIC mode. The mean deviation of the HPTLC method compared with the HPLC method was 0.9 mg kg-1 HMF in honey. Re-evaluation of the same HPTLC plate after one month showed a deviation of 0.5 mg kg−1 HMF in honey. It was demonstrated that the proposed HPTLC method is an effective method for HMF quantitation in honey. MediaObjects/216_2011_5081_Figa_HTML.gif
Keywords:
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号